-40%

Security Access System WOLFE GUARD Model AC-10 110 VAC

$ 401.27

Availability: 100 in stock

Description

The box of original packaging dirty.
The Wolfe AC-10 110V Machinery Access Control System is an indoor unit designed to limit access to power devices only to authorized users. Up to 99 users may be programmed with a 1-6 digit code. The AC-10 110V is wired for 110VAC devices only. Both sensed and unsensed switching is available. This will allow, for example, wiring both a saw (sensed) and a blower (unsensed) to the AC-10. The saw and the blower will turn on simultaneously when a valid code is entered. The saw maybe started and stopped over and over again using the trigger or switch on the saw. Each time the saw is turned off the AC-10 will sense that the deivise is not being used and Auto Shut-off timer will start. If the saw is started once again the timer will reset. If the saw is not used again and the timer runs out, the AC-10 will turn of power to both the saw and blower. To again allow power to the saw and to start the blower, re-enter a valid code.
Power Ratings: The AC-10 can control a maximum of 20AMPS or up to 1.5HP motor. Exceeding these ratings will cause permanent damage to the AC-10. The current sensor within the device can detect load over .150amps and up to 20amps. If the AC-10 senses more than 20amps through the red wire (due to a possible overload of the motor), the unit will automatically shut down and the red and green LED's will flash alternately indicating an overload condition.
Weather rating: The AC-10 is for indoor used only and should not be mounted outdoors.
Auto Shut-Off timer: when  a proper code followed by the * key is entered, the power will turned on to both the sensed and unsensed devise(s). The power will stay on as longas the sensed device is being used. After the sense device is turned off, the AC-10 senses the device is no longer drawing power (not being used) and the Auto Shut Off Timer starts. As a warning that the timer is about to run out, the AC-10 will flash green for the last 10 second of the timer. After the timer completely elapses(programmable from 10-990seconds), the AC-10 will turned off the power to the controlled device(s). A valid code must be entered to turned power on again. Power to the controlled device is on when the green LED is on solid or flashing. Power may also be turned off manually by pressing and holding any key for 1/2 a second.
Lockout Code: If there is some reason for which you donot want to let anyone operate the machinery being controlled (such as a worn belt which needs replacing for example). you can enter a "LOCKOUT" code, which will disable all "NORMAL" user codes from the operating machinery. A flashing red LED will indicate this "LOCKOUT" condition. Enter q "LOCKOUT" code again to release the AC-10from this condition.